File APDXII.RO

Directory of image this file is from
This file as a plain text file

.PAPER SIZE 60,72
.TAB STOPS 8,16,24,32,40,48,56,64
.HEADER TOP SPLIT UPPER ARABIC
.TITLE NP-8 SPUNLACED INSPECTION SYSTEM
.SUBTITLE COMPUTER ADDITION CERTIFICATION
.CHAPTER APPENDIX-II
.SKIP 25
.CENTER
APPENDIX-II
.BREAK
.CENTER
-----------
.PAGE
BRING UP THE COMPUTER SYSTEM PER OP-COM INSTRUCTIONS
.SKIP
CHECK STYLE TABLE FOR TST1 AND TST2
.SKIP
IF THESE STYLES ARE NOT IN THE STYLE TABLE YOU MAY ENTER
THEM OR SELECT STYLES THAT CLASSIFY DEFECTS AS SPECIFIED
IN NOTE 1
.SKIP
DISABLE BETA GAGE
.SKIP
SET ALL DISCRIMINATORS TO TEN
.SKIP
CONNECT SIMULATOR TO CHANNEL DRAWERS
.SKIP
SET INSPECTOR ON SIMULATED FOOT PULSES
.SKIP 10
.NOTE
NOTE 1
STYLE TST1 MUST CLASSIFY DEFECTS AS FOLLOWS:
.SKIP
.NOFILL
+TRAN = MAJOR
+REFL = MAJOR
-TRAN = CRITICAL
-REFL = CRITICAL
.SKIP
STYLE TST2 MUST CLASSIFY DEFECTS AS FOLLOWS:
.SKIP
+TRAN = CRITICAL
+REFL = CRITICAL
+REFL = MAJOR
-REFL = MAJOR
.END NOTE
.FILL
.PAGE

SET UP A + SMALL DEFECT IN LANE 1 .SKIP DECREASE THE TRANSMISSION + SENSITIVITY SETTING UNTIL THE "ALL DEFECT" INDICATOR LIGHTS .SKIP DECREASE THE TRANSMISSION + SIZE SETTING UNTIL THE "LARGE DEFECT" INDICATOR LIGHTS .SKIP THIS CAUSES A + TRANSMISSION DEFECT ONLY .SKIP AFTER APPROXIMATELY 20 SEC. THE "MAJOR DEFECT RATE EXCEEDED" MESSAGE SHOULD APPEAR ON THE CRT .SKIP WHEN THIS MESSAGE APPEARS THE "MAJOR RATE" INDICATOR, LOCATED ON THE MAIN CONSOLE, SHOULD LIGHT .SKIP ALSO THE ALARM, LOCATED IN THE REMOTE CONSOLE, SHOULD SOUND .SKIP THESE ALARMS MUST BE RESET AT THEIR RESPECTIVE LOCATIONS .SKIP RESETTING THESE ALARMS DOES NOT AFFECT THE COMPUTER .SKIP THE "M1" RATE SHOULD BEGIN TO INCREASE .SKIP THESE RATES WILL BE DISPLAYED ONCE PER MINUTE BECAUSE THE BETA GAGE IS DISABLED .SKIP RETURN ALL DISCRIMINATORS TO TEN .SKIP AFTER APPROXIMATELY 1 MINUTE THE "MAJOR DEFECT RATE NORMAL" MESSAGE SHOULD APPEAR ON THE CRT .SKIP THE "M1" RATE SHOULD BEGIN TO DECREASE .SKIP MOVE THE DEFECT TO LANE 2 AND REPEAT THE ABOVE PROCEDURE OBSERVING "M2" .SKIP MOVE THE DEFECT TO LANE 3 AND REPEAT THE ABOVE PROCEDURE OBSERVING "M3" .PAGE
SET UP A + SMALL DEFECT IN LANE 1 .SKIP DECREASE THE REFLECTION + SENSITIVITY SETTING UNTIL THE "ALL DEFECT" INDICATOR LIGHTS .SKIP DECREASE THE REFLECTION + SIZE SETTING UNTIL THE "LARGE DEFECT" INDICATOR LIGHTS .SKIP THIS CAUSES A + REFLECTION DEFECT ONLY .SKIP AFTER APPROXIMATELY 20 SEC. THE "MAJOR DEFECT RATE EXCEEDED" MESSAGE SHOULD APPEAR ON THE CRT .SKIP WHEN THIS MESSAGE APPEARS THE "MAJOR RATE" INDICATOR, LOCATED ON THE MAIN CONSOLE, SHOULD LIGHT .SKIP ALSO THE ALARM, LOCATED IN THE REMOTE CONSOLE, SHOULD SOUND .SKIP THESE ALARMS MUST BE RESET AT THEIR RESPECTIVE LOCATIONS .SKIP RESETTING THESE ALARMS DOES NOT AFFECT THE COMPUTER .SKIP THE "M1" RATE SHOULD BEGIN TO INCREASE .SKIP THESE RATES WILL BE DISPLAYED ONCE PER MINUTE BECAUSE THE BETA GAGE IS DISABLED .SKIP RETURN ALL DISCRIMINATORS TO TEN .SKIP AFTER APPROXIMATELY 1 MINUTE THE "MAJOR DEFECT RATE NORMAL" MESSAGE SHOULD APPEAR ON THE CRT .SKIP THE "M1" RATE SHOULD BEGIN TO DECREASE .SKIP MOVE THE DEFECT TO LANE 2 AND REPEAT THE ABOVE PROCEDURE OBSERVING "M2" .SKIP MOVE THE DEFECT TO LANE 3 AND REPEAT THE ABOVE PROCEDURE OBSERVING "M3" .PAGE
SET UP A - SMALL DEFECT IN LANE 1 .SKIP DECREASE THE TRANSISSION - SENSITIVITY SETTING UNTIL THE "ALL DEFECT" INDICATOR LIGHTS .SKIP DECREASE THE TRANSMISSION - SIZE SETTING UNTIL THE "LARGE DEFECT" INDICATOR LIGHTS .SKIP THIS CAUSES A - TRANSMISSION DEFECT ONLY .SKIP AFTER APPROXIMATELY 20 SEC. THE "CRITICAL DEFECT RATE EXCEEDED" MESSAGE SHOULD APPEAR ON THE CRT .SKIP WHEN THIS MESSAGE APPEARS THE "CRITICAL RATE" INDICATOR, LOCATED ON THE MAIN CONSOLE, SHOULD LIGHT .SKIP ALSO THE ALARM, LOCATED IN THE REMOTE CONSOLE, SHOULD SOUND .SKIP THESE ALARMS MUST BE RESET AT THEIR RESPECTIVE LOCATIONS .SKIP RESETTING THESE ALARMS DOES NOT AFFECT THE COMPUTER .SKIP THE "C1" RATE SHOULD BEGIN TO INCREASE .SKIP THESE RATES WILL BE DISPLAYED ONCE PER MINUTE BECAUSE THE BETA GAGE IS DISABLED .SKIP RETURN ALL DISCRIMINATORS TO TEN .SKIP AFTER APPROXIMATELY 1 MINUTE THE "CRITICAL DEFECT RATE NORMAL" MESSAGE SHOULD APPEAR ON THE CRT .SKIP THE "C1" RATE SHOULD BEGIN TO DECREASE .SKIP MOVE THE DEFECT TO LANE 2 AND REPEAT THE ABOVE PROCEDURE OBSERVING "C2" .SKIP MOVE THE DEFECT TO LANE 3 AND REPEAT THE ABOVE PROCEDURE OBSERVING "C3" .PAGE
SET UP A - SMALL DEFECT IN LANE 1 .SKIP DECREASE THE REFLECTION - SENSITIVITY SETTING UNTIL THE "ALL DEFECT" INDICATOR LIGHTS .SKIP DECREASE THE REFLECTION - SIZE SETTING UNTIL THE "LARGE DEFECT" INDICATOR LIGHTS .SKIP THIS CAUSES A - REFLECTION DEFECT ONLY .SKIP AFTER APPROXIMATELY 20 SEC. THE "CRITICAL DEFECT RATE EXCEEDED" MESSAGE SHOULD APPEAR ON THE CRT .SKIP WHEN THIS MESSAGE APPEARS THE "CRITICAL RATE" INDICATOR, LOCATED ON THE MAIN CONSOLE, SHOULD LIGHT .SKIP ALSO THE ALARM, LOCATED IN THE REMOTE CONSOLE, SHOULD SOUND .SKIP THESE ALARMS MUST BE RESET AT THEIR RESPECTIVE LOCATIONS .SKIP RESETTING THESE ALARMS DOES NOT AFFECT THE COMPUTER .SKIP THE "C1" RATE SHOULD BEGIN TO INCREASE .SKIP THESE RATES WILL BE DISPLAYED ONCE PER MINUTE BECAUSE THE BETA GAGE IS DISABLED .SKIP RETURN ALL DISCRIMINATORS TO TEN .SKIP AFTER APPROXIMATELY 1 MINUTE THE "CRITICAL DEFECT RATE NORMAL" MESSAGE SHOULD APPEAR ON THE CRT .SKIP THE "C1" RATE SHOULD BEGIN TO DECREASE .SKIP MOVE THE DEFECT TO LANE 2 AND REPEAT THE ABOVE PROCEDURE OBSERVING "C2" .SKIP MOVE THE DEFECT TO LANE 3 AND REPEAT THE ABOVE PROCEDURE OBSERVING "C3" .PAGE
TRANSITION TO STYLE TST2 PER OP-COM INSTRUCTIONS .SKIP A DEFECT LOG SHOULD BE FORMED AT THE SYSTEM TERMINAL AT THIS TIME .SKIP A PRODUCTION LOG SHOULD BE FORMED AT THE APPROPRIATE DEC WRITER .PAGE
SET UP A + SMALL DEFECT IN LANE 1 .SKIP DECREASE THE TRANSMISSION + SENSITIVITY SETTING UNTIL THE "ALL DEFECT" INDICATOR LIGHTS .SKIP DECREASE THE TRANSMISSION + SIZE SETTING UNTIL THE "LARGE DEFECT" INDICATOR LIGHTS .SKIP THIS CAUSES A + TRANSMISSION DEFECT ONLY .SKIP AFTER APPROXIMATELY 20 SEC. THE "CRITICAL DEFECT RATE EXCEEDED" MESSAGE SHOULD APPEAR ON THE CRT .SKIP WHEN THIS MESSAGE APPEARS THE "CRITICAL RATE" INDICATOR, LOCATED ON THE MAIN CONSOLE, SHOULD LIGHT .SKIP ALSO THE ALARM, LOCATED IN THE REMOTE CONSOLE, SHOULD SOUND .SKIP THESE ALARMS MUST BE RESET AT THEIR RESPECTIVE LOCATIONS .SKIP RESETTING THESE ALARMS DOES NOT AFFECT THE COMPUTER .SKIP THE "C1" RATE SHOULD BEGIN TO INCREASE .SKIP THESE RATES WILL BE DISPLAYED ONCE PER MINUTE BECAUSE THE BETA GAGE IS DISABLED .SKIP RETURN ALL DISCRIMINATORS TO TEN .SKIP AFTER APPROXIMATELY 1 MINUTE THE "CRITICAL DEFECT RATE NORMAL" MESSAGE SHOULD APPEAR ON THE CRT .SKIP THE "C1" RATE SHOULD BEGIN TO DECREASE .SKIP MOVE THE DEFECT TO LANE 2 AND REPEAT THE ABOVE PROCEDURE OBSERVING "C2" .SKIP MOVE THE DEFECT TO LANE 3 AND REPEAT THE ABOVE PROCEDURE OBSERVING "C3" .PAGE
SET UP A + SMALL DEFECT IN LANE 1 .SKIP DECREASE THE REFLECTION + SENSITIVITY SETTING UNTIL THE "ALL DEFECT" INDICATOR LIGHTS .SKIP DECREASE THE REFLECTION + SIZE SETTING UNTIL THE "LARGE DEFECT" INDICATOR LIGHTS .SKIP THIS CAUSES A + REFLECTION DEFECT ONLY .SKIP AFTER APPROXIMATELY 20 SEC. THE "CRITICAL DEFECT RATE EXCEEDED" MESSAGE SHOULD APPEAR ON THE CRT .SKIP WHEN THIS MESSAGE APPEARS THE "CRITICAL RATE" INDICATOR, LOCATED ON THE MAIN CONSOLE, SHOULD LIGHT .SKIP ALSO THE ALARM, LOCATED IN THE REMOTE CONSOLE, SHOULD SOUND .SKIP THESE ALARMS MUST BE RESET AT THEIR RESPECTIVE LOCATIONS .SKIP RESETTING THESE ALARMS DOES NOT AFFECT THE COMPUTER .SKIP THE "C1" RATE SHOULD BEGIN TO INCREASE .SKIP THESE RATES WILL BE DISPLAYED ONCE PER MINUTE BECAUSE THE BETA GAGE IS DISABLED .SKIP RETURN ALL DISCRIMINATORS TO TEN .SKIP AFTER APPROXIMATELY 1 MINUTE THE "CRITICAL DEFECT RATE NORMAL" MESSAGE SHOULD APPEAR ON THE CRT .SKIP THE "C1" RATE SHOULD BEGIN TO DECREASE .SKIP MOVE THE DEFECT TO LANE 2 AND REPEAT THE ABOVE PROCEDURE OBSERVING "C2" .SKIP MOVE THE DEFECT TO LANE 3 AND REPEAT THE ABOVE PROCEDURE OBSERVING "C3" .PAGE
SET UP A - SMALL DEFECT IN LANE 1 .SKIP DECREASE THE TRANSMISSION - SENSITIVITY SETTING UNTIL THE "ALL DEFECT" INDICATOR LIGHTS .SKIP DECREASE THE TRANSMISSION - SIZE SETTING UNTIL THE "LARGE DEFECT" INDICATOR LIGHTS .SKIP THIS CAUSES A - TRANSMISSION DEFECT ONLY .SKIP AFTER APPROXIMATELY 20 SEC. THE "MAJOR DEFECT RATE EXCEEDED" MESSAGE SHOULD APPEAR ON THE CRT .SKIP WHEN THIS MESSAGE APPEARS THE "MAJOR RATE" INDICATOR, LOCATED ON THE MAIN CONSOLE, SHOULD LIGHT .SKIP ALSO THE ALARM, LOCATED IN THE REMOTE CONSOLE, SHOULD SOUND .SKIP THESE ALARMS MUST BE RESET AT THEIR RESPECTIVE LOCATIONS .SKIP RESETTING THESE ALARMS DOES NOT AFFECT THE COMPUTER .SKIP THE "M1" RATE SHOULD BEGIN TO INCREASE .SKIP THESE RATES WILL BE DISPLAYED ONCE PER MINUTE BECAUSE THE BETA GAGE IS DISABLED .SKIP RETURN ALL DISCRIMINATORS TO TEN .SKIP AFTER APPROXIMATELY 1 MINUTE THE "MAJOR DEFECT RATE NORMAL" MESSAGE SHOULD APPEAR ON THE CRT .SKIP THE "M1" RATE SHOULD BEGIN TO DECREASE .SKIP MOVE THE DEFECT TO LANE 2 AND REPEAT THE ABOVE PROCEDURE OBSERVING "M2" .SKIP MOVE THE DEFECT TO LANE 3 AND REPEAT THE ABOVE PROCEDURE OBSERVING "M3" .PAGE
SET UP A - SMALL DEFECT IN LANE 1 .SKIP DECREASE THE REFLECTION - SENSITIVITY SETTING UNTIL THE "ALL DEFECT" INDICATOR LIGHTS .SKIP DECREASE THE REFLECTION - SIZE SETTING UNTIL THE "LARGE DEFECT" INDICATOR LIGHTS .SKIP THIS CAUSES A - REFLECTION DEFECT ONLY .SKIP AFTER APPROXIMATELY 20 SEC. THE "MAJOR DEFECT RATE EXCEEDED" MESSAGE SHOULD APPEAR ON THE CRT .SKIP WHEN THIS MESSAGE APPEARS THE "MAJOR RATE" INDICATOR, LOCATED ON THE MAIN CONSOLE, SHOULD LIGHT .SKIP ALSO THE ALARM, LOCATED IN THE REMOTE CONSOLE, SHOULD SOUND .SKIP THESE ALARMS MUST BE RESET AT THEIR RESPECTIVE LOCATIONS .SKIP RESETTING THESE ALARMS DOES NOT AFFECT THE COMPUTER .SKIP THE "M1" RATE SHOULD BEGIN TO INCREASE .SKIP THESE RATES WILL BE DISPLAYED ONCE PER MINUTE BECAUSE THE BETA GAGE IS DISABLED .SKIP RETURN ALL DISCRIMINATORS TO TEN .SKIP AFTER APPROXIMATELY 1 MINUTE THE "MAJOR DEFECT RATE NORMAL" MESSAGE SHOULD APPEAR ON THE CRT .SKIP THE "M1" RATE SHOULD BEGIN TO DECREASE .SKIP MOVE THE DEFECT TO LANE 2 AND REPEAT THE ABOVE PROCEDURE OBSERVING "M2" .SKIP MOVE THE DEFECT TO LANE 3 AND REPEAT THE ABOVE PROCEDURE OBSERVING "M3" .PAGE



Feel free to contact me, David Gesswein djg@pdp8online.com with any questions, comments on the web site, or if you have related equipment, documentation, software etc. you are willing to part with.  I am interested in anything PDP-8 related, computers, peripherals used with them, DEC or third party, or documentation. 