File CHRIO.SB (8k SABR macro assembler source file)

Directory of image this file is from
This file as a plain text file

//	CHRIO - CHARACTER I/O.
/
/	CALL CHRIO(IDEVN,ICHAR)
/
/	IDEV = FORT II DEVICE NUMBER.
/
/	ICHAR = 7 OR 8 BIT CHARACTER.
/
/	IF IDEV IS POSITIVE, THE CHAR IS OUTPUTTED.
/
/	IF IDEV IS NEGATIVE, THE NEXT CHAR IS
/	READ FROM THE DEVICE, AND PUT IN ICHAR.
/
//

	ENTRY CHRIO

OPDEF	TADI	1400
OPDEF	DCAI	3400

CHRIO,	BLOCK 2
	JMS GETP
	SPA		/WHAT IS DEVICE SIGN?
	JMP RCHAR	/NEG DEV.   MEANS READ.
	JMS SETDEV	/POS DEV.  MEANS WRITE.
	0000
	JMS GETP
	DCA ICHAR
	JMS CHSUB
	JMP XIT

IDEV,	0
ICHAR,	0
ADDR,	0

RCHAR,	CIA		/READ A CHAR.
	JMS SETDEV
	4000		/SET BIT FOR READ. (8 UNITS NOW!)
	JMS GETP
	CLA
	TAD CDFB
	DCA CDFCH
	JMS CHSUB
CDFCH,	HLT
	AND (177
	TAD (200
	DCAI ADDR
XIT,	CLA
	RETRN CHRIO

SETDEV,	0
	TAD (-1
	AND (7
	CLL RAR;RTR;RTR
	TAD I SETDEV
	INC SETDEV
	DCA IDEV
	JMP I SETDEV

CHSUB,	0
	TAD ICHAR
	AND (377
	TAD IDEV
	CALL 0,GENIO
	JMP I CHSUB

GETP,	0
	TAD CHRIO
	DCA CDFA
CDFA,	HLT
	TADI CHRIO#
	DCA CDFB
	INC CHRIO#
	TADI CHRIO#
	DCA ADDR
	INC CHRIO#
CDFB,	HLT
	TADI ADDR
	JMP I GETP

	END



Feel free to contact me, David Gesswein djg@pdp8online.com with any questions, comments on the web site, or if you have related equipment, documentation, software etc. you are willing to part with.  I am interested in anything PDP-8 related, computers, peripherals used with them, DEC or third party, or documentation. 