/76 / / /%R CHECK THE STATUS OF THE STACKER TRAYS / /%TW COME HERE ONCE PER CHOP VIA THE JUMP TABLE TO / MONITOR THE STATUS OF THE STACKER TRAYS. TURN / ON THE "TRAY NEEDED" INDICATORS AS REQUIRED AND / STOP THE FINISHING MACHINE IF NEEDED TRAYS / ARE NOT RETURNED IN TIME. WHEN ANY "TRAY NEEDED" / INDICATOR IS FLASHING, THE "TRAY OUT" MESSAGE IS / DISPLAYED ON THE OPERATOR'S CRT, AND THE ALERT / ALARM IS SOUNDED. / /%TW THE SAMPLE TRAY NEEDED LIGHT WILL COME ON AFTER / THE TRAY HAS BEEN OUT FOR 90 (DECIMAL) CHOPS. / IF THE SAMPLE TRAY IS OUT FOR MORE THAN 180 / (DECIMAL) CHOPS, THE MACHINE WILL STOP. / NORMAL SAMPLING IS INTERRUPTED WHENEVER THE SAMPLE / TRAY IS OUT. / /%TW WHEN A REJECT TRAY IS EJECTED, IT MAY STAY OUT / UNTIL THE ACTIVE REJECT TRAY SHEET COUNT IS / WITHIN 50 OF THE TRAY CAPACITY BEFORE THE TRAY / NEEDED INDICATOR COMES ON. IF THE TRAY IS STILL / OUT WHEN THE ACTIVE REJECT TRAY GETS WITHIN 15 / SHEETS OF ITS CAPACITY, THE MACHINE WILL STOP. / /%TW THE PRODUCT TRAY ARE HANDLED THE SAME AS THE / REJECT TRAYS. / / TRAYCK, 0 CLB DBRI52 AND P200 SZA CLA JMP I TRAYCK DBRI51 /READ THE TRAY POSITION DATA AND P7700 /ARE ANY STACKER TRAYS OUT ? SNA JMP I TRAYCK /NO, RETURN CLL RAL DCA WKA /YES, SAVE THE TRAY OUT DATA FOR LATER SNL CLA /IS THE SAMPLE TRAY OUT ? JMP TRAY1-1 /NO ISZ TRAYZ1 /YES, INCREMENT THE TRAY OUT COUNTER TAD TRAYZ1 /HAS THE TRAY BEEN OUT FOR MORE THAN 90 TAD (-132) /CHOPS, ABOUT 100 FEET ? SPA CLA JMP TRAY1 /NO, GO ON /77 TAD P40 /YES, GO SET UP TO TURN ON THE SAMPLE JMS TRAY5 /TRAY NEEDED INDICATOR. TAD TRAYZ1 TAD (-264) /HAS THE TRAY BEEN OUT FOR MORE THAN SPA CLA /180 CHOPS, ABOUT 200 FEET ? JMP TRAY1 /NOT YET, GO ON TAD P400 /YES, GO OPEN THE "TRAY OUT" INTERLOCK JMS INLOCK SKP DCA TRAYZ1 /CLEAR THE SAMPLE TRAY OUT CHOP COUNTER TRAY1, TAD WKA /ARE EITHER OF THE REJECT TRAYS OUT ? CLL RAL SMA SNL CLA JMP TRAY2 /NO, GO ON TO THE PRODUCT TRAYS TAD REJCNT /YES, DOES THE ACTIVE REJECT TRAY TAD (62) /CONTAIN MORE THAN 75 SHEETS ? SPA CLA JMP TRAY2 /NO, GO ON TAD REJFLG /YES, SET "TRAY NEEDED" LIGHT FOR THE SZA CLA /REJECT TRAY WHICH IS OUT TAD P10 /REJECT A TRAY OUT TAD P10 /REJECT B TRAY OUT JMS TRAY5 /GO SET UP TO TURN ON THE REQUIERED /REJECT TRAY NEEDED INDICATOR. TAD REJCNT /DOES THE ACTIVE REJECT TRAY CONTAIN TAD (17) /MORE THAN 110 SHEETS ? SPA CLA JMP TRAY2 /NO, GO ON TAD P400 /YES, GO OPEN THE "TRAY OUT" INTERLOCK JMS INLOCK TRAY2, TAD WKA /ARE ANY OF THE PRODUCT TRAYS OUT ? CLL RAL CLL RAL SNA CLA JMP TRAY4 /NO, GO ON TAD PROCNT /CONTAIN MORE THAN 75 SHEETS ? TAD (62) SPA CLA JMP TRAY4 /NO, GO ON DBRI51 /YES, SET UP TO TURN ON THE PROPER BSW /PRODUCT TRAY NEEDED INDICATOR. AND (7) JMS TRAY5 TAD PROCNT /DOES THE ACTIVE PRODUCT TRAY CONTAIN TAD (17) /MORE THAN 110 SHEETS ? SPA CLA JMP TRAY4 /NO, GO ON TRAY3, TAD P400 /YES, GO OPEN THE "TRAY OUT" INTERLOCK JMS INLOCK /78 TRAY4, CLB /IS ANY "TRAY NEEDED" INDICATOR ON ? TAD TRAYNF SNA CLA JMP I TRAYCK /NO, RETURN TAD TRAFLG /YES, IS THE TRAY OUT ALARM FLAG SET ? SZA CLA JMP I TRAYCK /YES, RETURN. DBRI52 /NO, ARE THE FIELD INPUTS DISABLED ? AND P40 SZA CLA JMP I TRAYCK /YES, RETURN. CIF 30 /NO, GO CUE THE "TRAY OUT" MESSAGE JMS I (CRTMSG) /FOR THE CRT DISPLAY. CRTM04 CLB IAC DCA TRAFLG /SET THE TRAY OUT ALARM FLAG JMP I TRAYCK /RETURN / / / SUBROUTINE TO "OR" BITS INTO THE TRAY NEEDED FLAG. / / TRAY5, 0 MQL /PUT THE NEW BIT IN THE M/Q REGISTER. TAD TRAYNF /GET THE OLD TRAY NEEDED FLAG MQA /"OR" IN THE NEW TRAY NEEDED BIT AND DCA TRAYNF /PUT THE DATA BACK IN THE FLAG. JMP I TRAY5 /RETURN TRAYZ1, 0